About Heavenly Designs & Construction
A NSW licensed, people-focused main contractor. We build to the NCC and Australian Standards, backed by deep remedial experience.
A solutions provider, not just a builder
No matter how we build, the right people in the right places are delivering the right solutions.
Heavenly Designs & Construction Pty Ltd is a NSW licensed main contractor based in Wattle Grove, led by Managing Director Monty Salama, delivering residential, commercial, remedial, renovation and heritage projects. Our principals bring the experience and knowledge to deliver the highest levels of safety, quality and integrity.
We use modern methods of construction and select the approach that suits each project, whether traditional, modern or a hybrid of more than one method. That choice is made with you at the start, based on your site, program and budget.
Built to the NCC and Australian Standards
Every project we deliver is planned, built and checked against the National Construction Code (NCC) and the Australian Standards (AS) that apply to it. Compliance is not something we look at only at the final inspection. It is built into how we price, program, supervise and sign off every stage of the job.
National Construction Code
We build to the NCC performance requirements and Deemed-to-Satisfy provisions for each building class, covering structure, fire safety, health and amenity, damp and weatherproofing, and energy efficiency.
Australian Standards
Materials, systems and workmanship are specified and installed in line with the relevant Australian Standards and the manufacturer's installation requirements.
Licensed and accountable
NSW contractor licence 350181C and Open builder licence 87554S. Our principals take personal responsibility for safety, quality and integrity on every site.
Australian Standards we work to
We follow the editions of these standards that are referenced by the NCC in force at the time of approval. Click a category to see each standard and how we apply it on site.
Waterproofing & wet areas5 standards
| AS 3740 | Waterproofing of domestic wet areasBathrooms, showers, laundries and toilets: membrane extent, falls to waste, hob and set-down details, puddle flanges and junctions between floors and walls. |
|---|---|
| AS 4654.1 | Waterproofing membranes for external above-ground use: MaterialsSelecting membranes rated for UV exposure, movement and the substrate on balconies, roofs, podiums and planter boxes. |
| AS 4654.2 | Waterproofing membranes for external above-ground use: Design and installationFalls, upturns at walls and doors, overflows, termination and drainage details for balconies, decks and roofs. |
| AS 4858 | Wet area membranesPerformance requirements for the liquid and sheet membranes we install in wet areas. |
| AS 3958.1 | Ceramic tiles: Guide to the installation of ceramic tilesTile bedding, movement joints and substrate preparation so tiles stay bonded over the membrane. |
Concrete, footings & masonry7 standards
| AS 3600 | Concrete structuresConcrete strength, cover to reinforcement, curing and durability for slabs, columns, plinths and repairs. |
|---|---|
| AS 1379 | Specification and supply of concreteOrdering and checking the right concrete grade, slump and supply documentation on site. |
| AS/NZS 4671 | Steel reinforcing materialsReinforcing bar and mesh grades used in new concrete and concrete cancer repairs. |
| AS 2870 | Residential slabs and footingsSite classification and slab and footing design for houses and duplexes, as detailed by the engineer. |
| AS 3700 | Masonry structuresBrick and block walls, mortar, wall ties, cavity flashings, damp-proof courses and weep holes. |
| AS 4773.1 & .2 | Masonry in small buildings: Design and ConstructionMasonry detailing and workmanship for houses and other small buildings. |
| AS 2699 | Built-in components for masonry constructionWall ties, lintels and damp-proof courses with the right corrosion protection for the exposure. |
Structure, framing & loads5 standards
| AS 1684 | Residential timber-framed constructionWall, floor and roof framing sizes, bracing and tie-down for timber-framed homes. |
|---|---|
| AS 4100 | Steel structuresStructural steel beams, columns, lintels and connections, as designed by the engineer. |
| AS/NZS 4600 | Cold-formed steel structuresLight-gauge steel framing and purlins. |
| AS/NZS 1170 | Structural design actionsDead, live, wind and earthquake loads that the engineer's structural design is based on. |
| AS 4055 | Wind loads for housingWind classification of the site, which sets bracing, tie-down, windows and roofing. |
Roofing, cladding, windows & glazing5 standards
| AS 1562.1 | Design and installation of sheet roof and wall cladding: MetalMetal roof fixing, laps, minimum pitch and flashing details. |
|---|---|
| AS 2050 | Installation of roof tilesTile fixing, battens and pointing for tiled roofs. |
| AS 4200.2 | Pliable building membranes and underlays: InstallationSarking and wall wraps that manage condensation and keep water out of the frame. |
| AS 2047 | Windows and external glazed doors in buildingsWindow ratings for wind, water penetration and air infiltration, and their installation. |
| AS 1288 | Glass in buildings: Selection and installationSafety glass in doors, balustrades, bathrooms and low-level glazing. |
Plumbing, drainage & services2 standards
| AS/NZS 3500 | Plumbing and drainageWater services, sanitary drainage, stormwater, roof drainage and overflows. Carried out by licensed plumbers. |
|---|---|
| AS/NZS 3000 | Electrical installations (Wiring Rules)All electrical work carried out and certified by licensed electricians. |
Site, safety & special conditions6 standards
| AS 2601 | Demolition of structuresPlanning and carrying out demolition safely, including services disconnection and staging. |
|---|---|
| AS 1926.1 | Swimming pool safety: Safety barriers for swimming poolsPool fencing heights, gates and non-climbable zones on projects with pools. |
| AS 3660.1 | Termite management: New building workTermite barriers and management systems for new homes and additions. |
| AS 3959 | Construction of buildings in bushfire-prone areasConstruction requirements for the site's Bushfire Attack Level (BAL), where applicable. |
| AS 1428.1 | Design for access and mobilityAccessible entries, paths and facilities on commercial projects, where required. |
| AS 4586 | Slip resistance classification of pedestrian surfacesChoosing floor and balcony tiles with the right slip rating for wet and outdoor areas. |
Codes, legislation & other references9 references
| NCC Volume One | Building Code of Australia: class 2 to 9 buildingsApartments, commercial and other multi-unit buildings. |
|---|---|
| NCC Volume Two | Building Code of Australia: class 1 and 10 buildingsHouses, duplexes, townhouses, garages, sheds and pools. |
| ABCB Housing Provisions | Deemed-to-Satisfy provisions referenced by NCC Volume TwoAcceptable construction practice for houses. |
| NCC Volume Three | Plumbing Code of AustraliaPlumbing and drainage requirements, used with AS/NZS 3500. |
| Home Building Act 1989 (NSW) | Licensing, contracts, statutory warranties and insuranceThe basis of our residential building contracts, licences and warranties. |
| Environmental Planning and Assessment Act 1979 (NSW) | Development and building approvalsDA, CDC, construction and occupation certificates. |
| Design and Building Practitioners Act 2020 (NSW) | Duty of care, registered practitioners and declared designsApplies to class 2 buildings and remedial building work. |
| Work Health and Safety Act 2011 (NSW) | WHS legislation and SafeWork NSW codes of practiceSafe work method statements, site safety and inductions. |
| The Burra Charter | Australia ICOMOS charter for places of cultural significanceThe conservation approach we follow on heritage projects. |
The codes and standards that apply depend on the building class, location and scope of each project. We confirm them with your engineer, designer and certifier before work starts. Australian Standards are published by Standards Australia; the NCC is published by the Australian Building Codes Board (ABCB).
We know what goes wrong, so we build it right
Remedial work is our specialty. We are regularly called in to fix leaking balconies, failed membranes, concrete cancer, cracked render and poorly flashed walls, often on buildings that are only a few years old. Every job means opening up the work and seeing exactly where shortcuts were taken.
That experience gives us the confidence and know-how to get it right the first time on every new build, renovation and heritage project. We build out the defects before they happen.
Waterproofing done properly
Correct falls, set-downs, hob heights, bond breakers, puddle flanges and upturns, installed to AS 3740 and AS 4654 and the membrane manufacturer's system.
Flashings and cavities
Continuous cavity flashings, sealed laps and clear weep holes, so water that gets behind the wall has a way out.
Concrete that lasts
The right concrete strength, cover to reinforcement and curing, so steel stays protected and concrete cancer does not start.
Movement and expansion joints
Joints placed and detailed where the structure needs to move, preventing cracked tiles, screeds and render.
Hold points and inspections
We inspect and photograph critical work, such as membranes, flashings and reinforcement, before it is covered up, and flood test wet areas where required.
Quality products, compatible systems
We use proven, certified products from trusted suppliers and never mix incompatible systems to save cost.
Request our capability statement
Get an overview of our services, licences, sectors and recent projects, ready to share with your team or development partners.